Gefen GEF-DVIKVM-848DL Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 49
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
26
RS-232 SERIAL CONTROL
General Functions
Function Description
#ACTIVEBOLO Enables the boot loader
#FADEFAULT Set matrix to default settings
#LOCKPOWER Toggles the lock power state
#MASKOUT Blanks selected outputs
#RMTIRADD Set the remote IR channel
#STBYMODE Sets the Matrix to Standby Mode
#ACTIVEBOLO Function
The #ACTIVEBOLO function enables the boot loader allowing the Matrix to be
updated with rmware using RS-232.
Syntax:
#ACTIVEBOLO
Parameters:
None
Notes:
The #ACTIVEBOLO command must be typed twice in order to activate the boot
loader.
#FADEFAULT Function
The #FADEFAULT function sets all Local EDIDs and routing settings to default,
turns off all FO 5V to inputs, sets IR address to 0, and disables #LOCKPOWER,
and #LOCKEDID.
Syntax:
#FADEFAULT
Parameters:
None
Vista de pagina 28