AUTOMATIC SECURITY CONFIGURATIO
N
1.
C
onnect the computer with the installed
G
e
f
en TV so
f
tware to the node
y
ou
wi
s
h t
o
se
t
as
th
e
M
as
t
e
r n
ode
.
2. Press and hold the
S
ecurit
y/
Reset button on the node
(
A
SC
M
)
, located on
the
f
ront panel,
f
or approximatel
y
2 seconds. The Power LED should be
g
in
to
ash RED, then release the button.
3
.A
f
ter approximatel
y
30 seconds, the Power LED should stop
ashin
g
and
g
low solid RED. This indicates that it is now a Master node. I
f
this node was
a
S
lave node
(
normal node
)
be
f
ore this process, it will now have a randoml
y
g
enerated A
SC
II Net ID and Encr
y
ption Ke
y
set.
4.
O
pen the
G
e
f
en TV
C
on
g
Tool
(
pa
g
e 12
)
. There should be a random
A
SC
II value as the Net ID. I
f
y
ou wish to use this Net ID
f
or the other
S
lave
n
odes, proceed to step 5.
O
therwise,
y
ou can now set
y
our own Net ID and
e
ncr
y
ption password which will be applied to all o
f
the
S
lave nodes in the
n
ext step. To do this, click on the local
ETH connected node” MA
C
address
and press the next button.
C
han
g
e onl
y
the Net ID and encr
y
ption password
elds and click on the next button.
O
nce the local node has been updated,
p
roceed to step 5.
5
. For this step to complete success
f
ull
y
, both the Master and
S
lave nodes
h
ave to be in A
SC
M. To do this, press and hold the
S
ecurit
y/
Reset button on
the Master node
f
or approximatel
y
2 seconds. The Power LED should be
g
in
ashin
g
RED. Within 30 seconds, press and hold the
S
ecurit
y/
Reset button
on the
S
lave node
(
s
)
f
or 2 seconds to enter A
SC
M. The
S
lave node’s Power
LED should also be
g
in to
ash while it receives the Net ID and Encr
y
ption
Ke
y
in
f
ormation
f
rom the Master node.
O
nce the Power LED on both the
M
aster and
S
lave nodes stop
ashin
g
and
g
low solid, the setup will be
c
omplete.
C
heck this b
y
openin
g
the
G
e
f
en TV
C
on
g
Tool and seein
g
that
a
ll n
odes
h
a
v
e
th
e
sa
m
e
N
e
t ID.
NOTE: I
f
the
S
lave nodes are located at a
g
reat distance
f
rom the Master node,
it is recommended that
S
tep 5 be repeated
f
or each
S
lave node separatel
y
.
The window that each device remains in A
SC
M is onl
y
30 seconds, and it ma
y
n
ot be possible to put all
S
lave nodes in the A
SC
M within the time
f
rame. It is
also possible to temporaril
y
relocate the
S
lave nodes to a coaxial port closer
to the Master node
f
or this con
g
uration process, and then move them to their
p
ermanent location a
f
ter this process is complete. I
f
a
S
lave node is accidentall
y
s
et as a Master node,
y
ou can hard reset the node b
y
pressin
g
and holdin
g
the
S
ecurit
y/
Reset button
f
or approximatel
y
10 seconds. This will revert the node to a
S
lave node and reset all internal con
g
urations to
f
actor
y
settin